AEROTOP® | Heating capacity Nominal (Maximal) [kW] / COP [A7/W35]* | Heating capacity Nominal (Maximal) [kW] / COP [A2/W35]* | Heating capacity Nominal (Maximal) [kW] / COP [A-7/W35]* | Energy efficiency** | Maximum flow temperature in °C | Sound power level L WA - outdoors [dB(A)] according to EN 12102 | Cooling capacity Nominal (Maximal) [kW] / EER [A35/W18] | Cooling capacity Nominal (Maximal) [kW] / EER [A35/W7] |
SX7 | 5,2 (5,5) / 5,2 | 5,0 (6,5) / 4,5 | 6,9 (7,0) / 3,3 | A+++ / A+++ | 60 | 47 | 9,9 (10,3) / 4,35 | 6,9 (7,3) / 3,35 |
SX10 | 8,0 (8,0) / 5,2 | 6,6 (9,5) / 4,2 | 9,7 (9,7) / 3,2 | A+++ / A+++ | 60 | 51 | 12,7 (14,6) / 4,26 | 9,6 (10,3) / 3,22 |
SX13 | 10,1 (10,1) / 5,13 | 7,48 (11,2) / 4,27 | 12,5 (12,5) / 2,91 | A+++ / A+++ | 60 | 51 | 13,0 (15,3) / 4,43 | 9,5 (11,2) / 3,49 |
* In accordance with EN 14511/ EN 14825
** Room heating: Product / system according to (EU) Ordinance no. 811/2013
Room heating
Product label range: A+++ to D
System label range: A+++ to G
Due to the refrigerant used, the AEROTOP® SX must maintain minimum distances from light wells or other openings leading into the building that are lower than the heat pump.
The refrigerant R32 is heavier than air and will sink to the ground in the event of a leak. As a result, a minimum distance between the outdoor unit and light wells must be maintained outdoors. When the light wells are close to the floor, this distance is ≥1000mm.
When an application has raised light wells (≥150 mm), the minimum distance between the outdoor unit and light wells must be ≥100 mm.
*Sound power data according EN 12102